Short answer

In commercial buildings, glass in critical locations, such as in and beside doors and low-level panes, must be safety glass that breaks safely or resists impact, under Approved Document K in England. Large glazed areas people could walk into need manifestation, visible markings at set heights. The Workplace (Health, Safety and Welfare) Regulations 1992 also require transparent surfaces in workplaces to be of safety material or protected, and marked where necessary.

Commercial Safety Glazing and Manifestation Rules Explained

Why the rules exist

People walk into glass, push against it and fall onto it. In busy commercial buildings, glazed doors, side panels, partitions and shopfronts are close to where people move, often quickly and while distracted. If ordinary annealed glass breaks under impact, it forms large, sharp shards that can cause serious injury.

The rules aim to reduce that risk in two ways. First, glass in the most vulnerable positions must either break safely, resist breaking or be protected by a barrier. Second, large areas of clear glass must be marked so people can see them and do not walk into them in the first place. Both apply to new installations and to replacement glass.

Critical locations explained

Approved Document K identifies critical locations where impact is most likely. Broadly, these are glass within doors and side panels near doors between floor level and a set height, and glass in walls and partitions between floor level and a lower set height. In these zones, the glazing must meet a safety classification, or be robust or small enough, or be protected so people cannot fall against it.

In practice, most commercial contractors specify toughened or laminated glass anywhere within these zones, and often throughout entrances and partitions for simplicity. Each pane of safety glass should carry a permanent mark showing it meets the relevant standard, which is useful when checking existing glass during a survey.

LocationRequirementTypical solution
Glass in doorsSafety glazing within critical zoneToughened or laminated glass
Side panels beside doorsSafety glazing within critical zoneToughened or laminated glass
Low-level panes in wallsSafety glazing below set heightToughened, laminated or barrier
Large clear areasManifestation at set heightsFrosted bands, logos, patterns
Glazed doors in glass screensDoor distinguishable from panelsManifestation, framing, hardware

Manifestation requirements

Manifestation is any permanent marking that makes glass visible. Approved Document K sets out that it should be provided on large uninterrupted areas of transparent glazing that people could collide with, at two heights to suit adults and children and wheelchair users. Markings can be bands, dots, logos, text or patterns, as long as they are clearly visible against the background on both sides.

Doors within glazed screens should also be distinguishable from the fixed panels around them, for example with contrasting frames, push plates and handles or a different manifestation pattern. Approved Document M covers visibility of glazed doors in non-domestic buildings and the needs of people with visual impairments, so good contrast matters.

  • Place markings at the two heights given in the guidance
  • Make sure markings contrast with what is seen behind the glass
  • Mark doors differently from fixed panels where possible
  • Use durable, permanent film or etching, not temporary stickers
  • Recheck manifestation after layout changes or new furniture

Workplace duties

Separate from Building Regulations, the Workplace (Health, Safety and Welfare) Regulations 1992 apply to most workplaces. Regulation 14 requires that windows and transparent or translucent surfaces in walls, partitions, doors and gates are, where necessary for health and safety, of safety material or protected against breakage, and are appropriately marked or incorporate features to make them apparent.

This means employers and those in control of premises should look at existing glazing, not just new work. An older office or shop with ordinary annealed glass in a vulnerable position may need it replaced with safety glass, protected with a barrier or covered with an approved safety film. A competent glazier can survey the premises and advise which panes need attention.

Safety film and older glass

Where replacing glass immediately is not practical, applying a suitable safety film can improve how existing glass behaves when it breaks, by holding fragments together. Films need to be the right type, correctly applied and maintained, and they do not suit every situation. They can also add manifestation, privacy or solar control at the same time.

For planned refurbishments, replacing vulnerable panes with toughened or laminated glass is usually the better long-term solution. When a pane breaks, it should always be replaced with glass that meets current safety requirements for its location, even if the original was ordinary annealed glass. Keep a record of which panes have been upgraded across your premises.

Checking your premises

A simple walk-round can highlight the obvious risks. Look at every glazed door, side panel, partition and low window, and check for safety marks in the corners of the glass. Note any areas of clear glass without markings, and any panes that have been damaged, chipped or scratched. Pay particular attention to busy entrances, corridors and areas used by children or the public.

Then get a qualified glazier to confirm what needs changing. They will check glass types, identify critical locations, recommend replacement, film or manifestation and give a prioritised list. Fire-rated glazing in escape routes should also be checked for damage and replaced only with like-for-like certified glass.

Questions people also ask

How do I know if glass is safety glass?

Safety glass normally has a permanent mark etched or printed in one corner showing the standard and classification it meets. If there is no mark, it may be ordinary annealed glass, or the mark may have been removed when it was cut. A glazier can assess unmarked glass and advise on replacement.

Do I need manifestation on glass doors?

Usually, yes, unless the door has features that make it obvious, such as substantial frames or large handles and push plates. Glazed doors within glass screens should be clearly distinguishable from the fixed panels. Approved Document K and M give guidance on manifestation and visibility in non-domestic buildings.

Is safety film as good as safety glass?

Correctly specified and fitted safety film can improve the performance of existing glass and reduce injury risk, but it is not identical to toughened or laminated glass. It suits interim upgrades and some low-risk locations. For new or replacement panes in critical locations, specifying safety glass is the more reliable approach.